Precise Temperature Control Across a Wide Range – Covers 0–100°C with ±0.2°C accuracy (20–40°C), ±0.5°C uniformity, and 0.1°C resolution, ensuring consistent and reproducible incubation results.
Flexible Heating & Cooling Rates – Offers 4 selectable heating rates (MAX, 5, 2, 1°C/min) and 4 cooling rates (MAX, 2, 1, 0.5°C/min) , allowing customized temperature ramping for different experimental needs.
Powerful & Versatile Mixing Performance – Delivers 250–3000 rpm mixing speed with a 3.0 mm orbit (on 100C/100 models), compatible with sample volumes from 0.1 mL to 50 mL and interchangeable blocks for various tube and plate formats.
Intuitive Multi‑Step Programming – Supports up to 5 program steps with 999 cycles, plus Quick Run mode for single‑step operations, pre‑heating function, low‑temperature storage (4–20°C), and auto‑recovery after power failure for enhanced convenience.
User‑Friendly 7‑Inch Touchscreen Interface – Displays real‑time temperature, speed, and program progress on a large color screen, with built‑in calibration for 4 temperature points (10/40/70/95°C or 45/60/80/95°C) to maintain long‑term accuracy.
| Parameter |
Specification |
Parameter |
Specification |
| Model |
100C / 100 / D100C |
Type |
Heating/Cooling/Mixing (100C, D100C) Heating/Mixing (100) |
| Display |
7‑inch color touchscreen |
Sample Capacity |
0.1 – 50 mL |
| Standard Block |
24 × 1.5 mL (other blocks available) |
Temperature Control Range |
100C/D100C: ambient‑15°C to 100°C 100: ambient+5°C to 100°C |
| Temperature Setting Range |
0 – 100°C |
Temperature Accuracy |
±0.2°C (20–40°C) ±0.5°C (<20 or >40°C) |
| Temperature Uniformity |
±0.5°C |
Temperature Stability |
±0.5°C |
| Temperature Resolution |
0.1°C |
Speed Range |
250 – 3000 rpm (100C/100) N/A (D100C) |
| Mixing Orbit (Diameter) |
3.0 mm (100C/100) |
Heating Rates |
MAX, 5, 2, 1 °C/min |
| Cooling Rates |
MAX, 2, 1, 0.5 °C/min (100C/D100C) |
Program Steps |
Up to 5 steps per program |
| Cycle Times |
Up to 999 cycles |
Timer Range |
0 – 99 h 59 min 59 s |
| Calibration Points (100C/D100C) |
10, 40, 70, 95 °C |
Calibration Points (100) |
45, 60, 80, 95 °C |
| Pre‑heating Function |
Yes (0–100°C) |
Low Temp Storage |
Yes (4–20°C) |
| Auto Recovery |
Yes (after power failure) |
Heated Lid |
Optional (block temp +5 to +20°C) |
| Maximum Power |
300 W |
Power Supply |
110–220 V AC, 50/60 Hz |
| Weight (with std. block) |
<10 kg |
Dimensions (L×W×H) |
332 × 227 × 185 mm |
| Recommended Ambient Temp. |
10 – 30°C |
Relative Humidity |
≤70% |







.png?w=1464&h=600)